Tripp Lite PDU Metered ATS 1.9kW 120V 20A 16 5-15/20R 2 L5-20P 1URM TAA

Mfg.Part: PDUMH20AT | CDW Part: 1164380 | UNSPSC: 39121017
Availability: 3-6 Business Days
Warranties
Was $879.48
Advertised Price
Product Details
  • Single phase 20A 120V Auto Transfer Switching/ ATS PDU
  • Provides a redundant A/B power option for non-redundant networking equipment
  • Digital display continuously reports total output power consumption in amps
  • 16 NEMA 5-15/20R outlets (8 front/ 8 rear); 2 NEMA L5-20P/5-20P inputs 12ft. cord
  • 1U horizontal rackmount
  • PDU/ Power Distribution Unit/ Horizontal PDU/ Metered PDU/ rack pdu/ pdus/ data center pdu/ network pdu/ networking pdu
  • 2 Year Tripp Lite Warranty
View Full Product Details
Better Together
Tripp Lite PDU Metered ATS 1.9kW 120V 20A 16 5-15/20R 2 L5-20P 1URM TAA
Quick View
Total Price:

Product Overview

Main Features
  • Single phase 20A 120V Auto Transfer Switching/ ATS PDU
  • Provides a redundant A/B power option for non-redundant networking equipment
  • Digital display continuously reports total output power consumption in amps
  • 16 NEMA 5-15/20R outlets (8 front/ 8 rear); 2 NEMA L5-20P/5-20P inputs 12ft. cord
  • 1U horizontal rackmount
  • PDU/ Power Distribution Unit/ Horizontal PDU/ Metered PDU/ rack pdu/ pdus/ data center pdu/ network pdu/ networking pdu
  • 2 Year Tripp Lite Warranty
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer
Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U is rated3.00 out of5 by2.
Rated 5 out of 5 by from Special Price because it doesn't have the controller boardThe Controller board you want to order with this apparently is the SNMPWEBCARD. It's cheaper to get it with the unit. If you don't need web admin, then this unit is perfect.
Date published: 2013-01-09T00:00:00-05:00
Rated 5 out of 5 by from Strange Detachable CordHi I have received my order from one of our suppliers and after opening the box I found out that the second source cord is strangely detachable! As long as this product is supposed to service the critical single corded IT loads, I could not figure out the reason for making it so! The other feature which a couldn't find was the ability to change between primary and secondary sources without rewiring and make outage to the loads! I have found other manufactureres products more expensive but with better features!
Date published: 2014-01-03T00:00:00-05:00
Rated 5 out of 5 by from I Would Buy this Product AgainVery nice product. Small Form Factor fits well in small places. Easy to setup and quite.
Date published: 2018-05-23T00:00:00-04:00
Rated 5 out of 5 by from Tested for yearsWe run an enterprise network for 250 End Users with multiple applications and systems. These devices are a nice tool for the price to help monitor the network and give some insurance in case a power source fails. I have had 4 of these online for years. No issues. The display indicates the amperage on the bus, which allows me to better balance my loads. I know exactly what is on each of my UPS systems. The fail over is fast enough from Pri to Sec to not lose a load. The Net card also allows for environmental monitoring, Input monitoring and control, as well as Load Control for cycling a load when needed. You can also shed your load so critical systems stay on the UPS longer.
Date published: 2016-01-19T00:00:00-05:00
Rated 5 out of 5 by from Test ResultsI've done extensive tests on this switch in order to compare and recommend the best solution for our single cord devices in data centers. The switching time of this product is unbelievable! Even with totally out of phase inputs. The only thing that I do like that this switch had is preferred source selection button in front panel which gives more flexibility.
Date published: 2014-04-08T00:00:00-04:00