Quick tech specs
  • 5kW single-phase ATS/ Switched PDU 208V 2U horizontal w/ 19 outlets and two 10ft cords
  • Enables redundant-power option for single-corded network devices
  • 19 outlets (16 C13/ 2 C19/ 1 L6-30R); 2 L6-30P input 10ft cords
  • PDU/ Power Distribution Unit/ PDU Strip/ Switched PDU/ rack pdu/ pdus/ datacenter pdu/ network pdu/ Horizontal PDU/ ATS PDU
  • Separate primary/secondary inputs connect to any two compatible power sources
  • Network interface and visual current meter
View All

Know your gear

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Availability: Item Backordered

Enhance your hardware

Add Warranty

Better Together

Tripp Lite PDU Switched ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM
Quick View
Total Price: